• Pro-CS Electric

    National Oilwell Varco® offers Choke Control Systems as stand alone systems or as an integrated part of Procon HP Manifold packages.

    Description

    National Oilwell Varco® offers Choke Control Systems as stand alone systems or as an integrated part of Procon HP Manifold packages. The Control Systems are designed to suit all types of drilling installations including semis, drillships, fixed platforms, jackups and more.

    The Control Systems are built to meet the offshore industry rules and regulations and are  customized to the client’s specifications.

    The hydraulic Local Control Panel is a complete system including all valves, instruments, wiring and tubing. It can be connected to an electric Remote Control Panel ensuring full usability.

    The Local Control Panel and Remote Control Panel can be delivered together with equipment such as Choke and Kill Manifolds, High Pressure Manifolds, Mud Gas Separator, Liquid Seal and Drilling HP Hoses as a complete system providing less interface for the client.

    Remote Control Panel (Electric)
    The compact Remote Control Panel is not only accommodating to various process designs. The flexible installation options are developed to optimize the clients working conditions. This display unit of the electric Remote Control Panel can be installed in the Drillers Cabin and hardwired to the location of the Control Cabinet. Providing easy access to all functions of the Remote Control Panel.

    Features/Benefits

    Features

    • Easy to operate – intuitive screen layout
    • Safety precautions – two handed operation
    • Field proven technology
    • Simplified actuation of valve operations
    • Readouts of pressure and temperature on all lines for Choke and Kill Manifold, Mud Gas Separator, Auxiliary and Primary Mud Standpipe Manifolds
    • System functions tailored to suit each project based on customer requirements
    • Built to suit Zone 2 installation. Adaptations to achieve Zone 1 installation possible if requested
    • System interface accurately reflected in DCDA
    • Alarm page with descriptive information

    Specifications

    Technical Specifications

     


    MODEL NoPro-CS Electric
    Design temperature0 to 40°C (32 - 104°F)
    Dimensions (Control Cabinet)800 x 300 x 1000 mm (l x d x h)
    Nominal voltage (UPS)120 – 230VAC
    Nominal frequency50 – 60 Hz
    Nominal power consumption150 W
    Max power consumption300 W
    In rush<30A

    Example approved for installation in zone 2. Please inquire for customization to achieve zone 1 requirements

    NOTE!      Please note that the contents of this flyer may be changed without warning. Drawings and measurements must not be used for construction.